1. ECO machine broken ink: when playing figure squares grating spoils, need a swab dipped in water scrubbing grating, should be wiped a few times more with dry cotton water wipe clean.
2. ECO machine print dislocation: 1.belt pulley card, need to adjust the belt pulley. 2. Servo motor is broken, need to replace the servo motor. 3. Copper ring is dirty, need to clean or replace copper ring.
3. ECO machine without print ink: 1) headboard fever, need to close the machine to rest. 2) This head cable is broken, need to replace the head cable. 3) nozzle clogged, need to smoke wash a shower nozzle. 4) the refill tube interface is blocked, it is necessary to remove the plug a few times more. 5) nozzle interference, interchangeable nozzle position, and with a paper towel pad between the nozzle and get an electric shock with is to check the nozzle interference, replace the nozzle.6) In the event of the nozzle out of ink at the same time, after exclusion of nozzle interference is not out of the ink is the headboard is broken.
4. ECO machine play figure line inclined to one side: 1.servo motor is broken, need to replace the servo motor. This grating sensor is dirty, need to use cotton swabs dipped in water scrub. Grating sensor is broken, need to change.
5. ECO machine is powered aircraft crashed car frame on the left: 1.grating sensor is dirty, need to be cleaned. This grating sensor is broken, need to change. 3. Cable not good, need to insert a few times more.
6. ECO machine play figure drops of ink: 1. nozzle in air pumped, not need to spend a few times. This refill tube interface joint is bad, need new insert or change the interface. 3. Sprinkler leakage, need to find out where the leak and then use glue sealing.